Tiltic (Hi level indicator sensor for extremely rough environment)

Electronic unit 2402.
![]() |
![]() |
The electronic control unit sets the time to energise/dienergise the relay and how sensitive the sensor shall be. The sensitivity and function of the device is controlled by two knobs telling the relay on and relay off time (variable from 0 to 10 sec). Whith a switch on top of the 2402 you can select if you want the relay to be normaly conected or normaly open (NC/NO).
|
1 2 3 |
1. Tiltic with wings 2. Tiltic with rubber tube. 3. Tiltic standard |
Product data
| Sensor Tiltic | Electronic unit 2402 | |
| Powersupply | 5-26 VDC | 230VAC, 50Hz/24 VDC |
| Power dissipation | 5-26mA (not loaded) | 2.5W (max) |
| Output signal | PNP/NPN max 1 Amp | Relay 1 pole 8A |
| Time delay | None | 0-10 sec on, 0-10sec off |
| Tilt angle | 17° from vertical in all directions | Not applicable |
| Temperature range | -40 to +60° C | -30 to +60° C |
| Enclosure classification | IP67 | IP20 |
| Material | Aluminium | Plastic (noryl & polycarbonat) |
| Surface material | Epoxy paint | Plastic (noryl & polycarbonat) |
| Cable | 4 metre 3wire highly flexible polyuretan with bending protection in non corrosive steel . | Not applicable |
| Protection tube | Oil resistant rubber | Not applicable |
| Size | se below | 34.5 x 78 x 88 mm (w, h, d) |
Mer data på Tiltic skall finnas att tillgå här